About the Touch Screen and User Interface
4-19
Part 1126187_05
E
2021
Nordson Corporation
Output Status - Details
Pin Assignment
on I/O
Connector
Input
Description
2
Any alert
Output is energized (On) whenever an alert is generated.
3
Any fault
Output is energized (On) whenever a fault is generated.
6
Standby Active
Output is energized when heaters are in Standby mode.
1
Ready
Unit is powered On, no fault is present (alerts do not
inhibit ready), the Master Heater control is switched On,
and the Cartridge and Nozzle zones are at set point
temperature.
8
Product Complete
When active, indicates that a product has been
completed. This output stays active until a new product is
started.
4
Low cartridge level
Active when the cartridge adhesive level reaches a
predefined level.
5
Empty cartridge
Active when the cartridge adhesive level reaches its
predefined level.
7
Running
Active when a product is jetting.
N/A
Jetting Applicator Control
An analog output that controls the waveform applied to
the piezo element.
N/A
Dump pressure
A second solenoid output that removes pressure from the
cartridge.
Summary of Contents for Vulcan Jet
Page 26: ...Description 2 8 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Page 162: ...Parts 9 4 Part 1126187_05 E 2021 Nordson Corporation Figure 9 2 Vulcan Jet applicator parts...
Page 163: ...Parts 9 5 Part 1126187_05 E 2021 Nordson Corporation Figure 9 3 Vulcan Jet applicator parts...
Page 171: ......
Page 172: ......