Advanced Controller Configuration
6-16
Part 1126187_05
E
2021
Nordson Corporation
Managing Applicator Service Reminders
Both of these components wear in time, causing poor jetting performance.
The following details how to modify and resolve these reminders in greater
detail.
Modifying the Seal Pack and Needle Seat Service Reminders
You can define when you want the system to display an Alert pop-up
message and a service reminder icon in the top status bar when either the
Seal Pack and/or the Needle Seat should be replaced.
Item
Default
Minimum
Maximum
Seal Pack
40 Cycles/million
20 Cycles/million
100 Cycles/million
Needle Seat
100 Cycles/million
20 Cycles/million
200 Cycles/million
System
Formats/Units
Date/Time
Service Reminders
Language
System Security
Display
Administration
System Information
07/14/15 2:37 PM
English
Service Reminders
Cycles/Million
Seal Pack
Cycles/Million
Needle Seat
30,000,000
100,000,500
1. From the
Home
screen, do one of the following:
S
Touch
.
S
Touch
, then touch
button.
2. Touch
Cartridge.
3. Touch
Cartridge Level Thresholds.
Enter the low level adhesive
amount (mL) at which you want to receive an Alert or Fault message.
4. Touch
.
NOTE:
Numbers appearing in yellow correspond to the item that should be
replaced.
Summary of Contents for Vulcan Jet
Page 26: ...Description 2 8 Part 1126187_05 E 2021 Nordson Corporation This page intentionally left blank...
Page 162: ...Parts 9 4 Part 1126187_05 E 2021 Nordson Corporation Figure 9 2 Vulcan Jet applicator parts...
Page 163: ...Parts 9 5 Part 1126187_05 E 2021 Nordson Corporation Figure 9 3 Vulcan Jet applicator parts...
Page 171: ......
Page 172: ......