About the Touch Screen and User Interface
4-10
Part 1126187_05
E
2021
Nordson Corporation
Monitoring the Pressure Zone
(contd)
Table 4‐1 Pressure State Color Reference
Button
Color
Status
Notes
Pressure
20 PSI
Bright
green
Ready/OK
The pressure zone is ready for operation.
Pressure
20 PSI
Light green
Waiting for
Ready
One of the following is true:
S
The system itself and/or one or both of the heated
zones are in a fault condition.
S
The system is either in the process of heating, or the
system is in Standby mode.
Pressure
15 PSI
Red
Fault
System pressure has either risen above or fallen below
the Fault threshold level.
NOTE:
In a fault condition, the Master Heater control
is switched Off. Production stops.
NOTE:
S
You can modify the pressure set point regardless of system state or
status.
S
The state of a zone is independent of the overall status of the
applicator/controller.