Advanced Controller Configuration
6-10
Part 1126187_05
E
2021
Nordson Corporation
Advanced Pressure Settings
Modifying Pressure Compensation
Use this option to help the system compensate for changes in adhesive
viscosity over time.
NOTE:
S
The controller has a built-in maximum pressure tolerance of 50 PSI
before causing a Fault condition.
S
When purging, the system uses this pressure set point along with the
current Input Wave Form settings.
Default
Minimum
Maximum
Disabled
---
---
2 PSI
0.5 PSI
5 PSI
0.14 Bar
0.03 Bar
0.34 Bar
13.79 kPa
3.45 kPa
34.47 kPa
Settings
Pressure Compensation
Bar/hr
Pressure
Enabled
Disable
1. From the
Home
screen, do one of the following:
S
Touch
.
S
Touch
, then touch
button.
2. Touch
Pressure.
3. Touch
Pressure Compensation.
If you decide to Enable this feature,
enter the pressure compensation value you want want to use.
4. Touch
.
Summary of Contents for Vulcan Jet