58
Instructions Manual
6. Maintenance
The drums are equipped with 2 cleaners each.
The function of these cleaners is to prevent
the accumulation of material underneath the
drums. Frequently check if the cleaners are in
good condition.
6.4- Cleaners
ATTENTION!
Turn off the tractor and remove
the ignition key before starting
the following procedure.
The cleaners are reversible, when one side is
worn out, assemble it in the another drum,
using its other side.
Immediately replace worn or damaged
double-sided cleaners.
To change the cleaners (K):
1.
Remove the bolt (N) using an Allen key
of 6 mm;
2.
Insert new cleaner and fix with the bolt
(N).
N
K
The use of PPE (suitable gloves and safety
glasses) is mandatory during the above
procedure.
ATTENTION!
6.4.1- Changing or reversing the
cleaners
Reverse the drum cleaners when
worn.