9
Installation and quick start commissioning guide - Commander ID300/302
5511 en - 2017.06 / a
GENERAL INFORMATION
1.4 -
Electrical characteristics
1.4.1 -
General characteristics
Characteristics
Level
Maximum supply imbalance
2 % negative phase sequence (equivalent to 3 % voltage imbalance
between phases).
Starts per hour
By electronic control: unlimited
By interrupting the AC supply: ≤ 20 (equally spaced)
Motor frequency variation range
From 10 to 150 Hz maximum. The range can be different depending if a
drive fan
(1)
is fitted or not, if this is a motor or a gear-motor and if this is a 2
pole motor or a 4 pole motor. For more information, please refer to the
brochure ref.5590.
(1)
Some drive and motor associations need the drive fan fitted as standard. These
associations can be found in section 1.4.2.
Efficiency
IES2 level according to EN 61800-9-2
Overload
150% of the full rated output current for 60 seconds or 180% for 3 seconds,
10 times per hour
Mains supply voltage and
frequency
200 V drive: 200 V to 230 V ±10 %, 1 phase or 3 phases
400 V drive: 380 V to 480 V ±10 %, 3 phases
Frequency range: 45 to 66 Hz
1.4.2 - Commander ID300/302 ratings
Commander ID300/302
with non IE motors
Supply
Commander
ID300 drive
LS Motor
Voltage
Max input
current
Size
Ref.
Output
current
Polarity
Output power
(V)
(A)
(A)
4 poles
2 poles
kW
Hp
230V
1 ph / 3ph
4.5
1
12017
1.7
LS 71M
-
0.25
0.33
5.3
12024
2.4
LS 71M
0.37
0.5
8.1
12030
3.0
LS 71L
0.55
0.75
Supply
Commander
ID300/302 drive
LS Motor
Voltage
Max input
current
Size
Ref.
Output
current
Polarity
Output power
(V)
(A)
(A)
4 poles
2 poles
kW
Hp
400V
3 ph
1.6
1
14012
1.2
LS 71M
-
0.25
0.33
2.2
14015
1.5
LS 71M
0.37
0.5
2.9
14018
1.8
LS 71L
0.55
0.75
: Standard motor and drive associations