13
Installation and quick start commissioning guide - Commander ID300/302
5511 en - 2017.06 / a
GENERAL INFORMATION
1.8 -
Options
Type
Option
Name
Details
LED and
Command
side flanges
(can be
mounted either
side of the
Commander
ID300/302)
ID-RUN-POT-
LED-FLANGE
• 1 potentiometer, connected to drive control terminal 1
to 3
• 3 command buttons, connected to drive control
terminal 9 & 10:
Run F Run R Stop (no reset)
• 3 LED, connected to drive control terminal 5
LED
colour
LED function
Permanent
Flashing
Red
Trip
(refer to section 5.1)
Alarm
ON for 500 ms
OFF for 500 ms
(refer to section 5.3)
Green
Supply OK
Drive active
ON for 4 s
OFF for 500 ms
Yellow
No function affected by default
(see the user and technical guide ref.5512)
ID-POT-LED-
FLANGE
• 1 potentiometer, connected to drive control terminal 1
to 3
• 3 LED, connected to drive control terminal 5
See above for LED functionalities.
ID-LED-
FLANGE
• 3 LED, connected to drive control terminal 5
See above for LED functionalities.
ID-BASE-
FLANGE
• Blank flange (e.g. if a fieldbus network is used)
Basic flange of a standard Commander ID300/302
Cable entry
side flanges
ID-4 CABLE-
FLANGE
• 4 plugs: 1xM25 + 1xM20+ 2xM16
Two option kits of 4 cable glands (plastic or EMC) are
available.
Basic flange of a standard Commander ID300/302. It
can be mounted either side of the Commander
ID300/302.
ID-3 CABLE
-RJ45
-FLANGE
• 3 plugs: 1xM25 + 1xM20 + 1xM16
Two option kits of 3 cable glands (plastic or EMC) are
available.
• RJ45 connector: allows a Field keypad RTC or a PC
laptop to be connected to the drive. With CT comms
cable (USB/RJ45) and “Connect” software, the user
can set, monitor or make diagnostics of the drive from
his PC laptop.
This flange can only be mounted on the right seen
from the motor drive end.