5
Installation and quick start commissioning guide - Commander ID300/302
5511 en - 2017.06 / a
GENERAL INFORMATION
1 - GENERAL INFORMATION
CAUTION
The characteristics given in this section are for
40 °C (104 °F), 1000 m altitude and 3 kHz swit ching
frequency. De-rating is required for higher swit-
ching frequencies, ambient temperature >40 °C
(104 °F) and high altitude. For more information,
please contact Leroy-Somer.
1.1 - General operating principle
The Commander ID300/302 is the association of
a 3-phase induction motor of IMfinity range and an
integrated high performance variable speed drive.
The Commander ID300/302 can be used with a large
panel of options for motor and drive, that allows the
product to perfectly suit application needs.
The motor can be offered in several mounting
arrangements (foot, flange) and can be combined
with standard gearboxes and brake from Leroy-Somer
ranges.
Drive software and parameter structure are common
with other drive ranges allowing easy commissioning
for users who are already familiar.
With the benefit of Leroy-Somer expertise in motor and
drive solution, the Commander ID300/302 integrates a
high performance motor control.
In the standard version, the drive with integrated
commands (side option flanges) does not require any
connection other than the power supply and the enable
or Safe Torque Off inputs.
The drive can support one I/O or fieldbus option module
(one internal slot available).
1.2 - Designation and presentation
1.2.1 - Drive designation and label
ID30x -
2 2 057
Commander ID300 designation
Model
Electrical Specifications
Product Line
Commander
ID300 : 1 x Enable input
ID302 : 2 x STO* inputs
Drive frame size:
1 à 3
Voltage rating:
2 - 200 V (200-230 ±10 %)
4 - 400 V (380-480 ±10 %)
Current rating:
Drive Rated current (A) x10
(*) Safe Torque Off
www.commanderID300.info
Type 1 - EN 60529 : IP55
OUTPUT
See motor
name plate
INPUT
200-230V / 14.3A
1 or 3 phases
Frequency
50Hz / 60Hz
ID 300-22057
IND.CONT.EQ.
554DN
E211799
Commander ID300 Label
Drive
reference
Approvals
Internal
use
(tracking)
Commander ID300
website address
Ingress
Protection
Input Voltage /
Typical Input
Current
Input
Frequency