14
Installation and quick start commissioning guide - Commander ID300/302
5511 en - 2017.06 / a
GENERAL INFORMATION
Type
Option
Name
Details
Braking
resistors
ID-SIZE1-
DBR200
ID-SIZE3-
DBR400
• For size 1 and 2 drives, use ID-SIZE1-DBR200:
Resistor 200W, 200 Ω
• For size 3 drive, use ID-SIZE3-DBR400:
Resistor 400W, 100 Ω
Mounting arrangements: back side of the drive (new
drive dimensions: W = 296 x D = 140 (mm) for sizes 1 &
2, W = 410 x D = 243 (mm) for size 3).
CAUTION
For sizes 1 and 2, a fan drive and a braking resistor
cannot be fitted at the same time.
Drive fans
ID-SIZE1-FAN
ID-SIZE3-FAN
• For size 1 and 2 drives, use ID-SIZE1-FAN
• For size 3 drive, use ID-SIZE3-FAN
IP68, 60 mA, 60W
Mounting arrangement: back side of the drive (new
drive dimensions: W + 277 (mm) for sizes 1 & 2, W +
390 (mm) for size 3).
CAUTION
For some drive and motor associations, the drive
fan is fitted as standard. See section 1.4.2.
Keypads
ID-SIZE1-
Keypad
ID-SIZE3-
Keypad
• For size 1 and 2 drives, use ID-SIZE1-Keypad
• For size 3 drive, use ID-SIZE3-Keypad
Integrated Keypad, LCD display, IP66
Main functions: Speed display, Drive status, Motor
commands, Parameter settings
Mounting arrangement: replaces standard terminal
cover (new drive dimensions: H + 24.5 mm). This option
has to be mounted by the user. Please refer to the
relevant mounting documentation.
Field Keypad
RTC
Remote keypad with a LCD display and real time clock
Main functions: Speed display, Drive status, Motor
commands, Parameter settings, real time clock
Mounting arrangement: This option has to be
connected by the user, using drive RJ45 connector of
ID-3 CABLE RJ45 FLANGE option. Please refer to the
relevant mounting documentation.
Fieldbus
ID-SIZE1-
PROFIBUS
CANopen
DeviceNet
Ethernet
EtherCAT
• For size 1 and 2 drives: fieldbus cover box
Mounting arrangement: replaces standard terminal
cover (new drive dimensions: H + 41.5 mm). This option
has to be mounted by the user. Please refer to the
relevant mounting documentation. The I/O expansion
option cannot be fitted at the same time.
2 x M12 clip-on connectors are available to allow quick
fieldbus connection
SI-
PROFIBUS
CANopen
DeviceNet
Ethernet
EtherCAT
• For size 3 drive: fieldbus module.
Mounting arrangement: This option has to be fitted to
the option slot and connected by the user. Please refer
to the relevant mounting documentation. The I/O
expansion option cannot be fitted at the same time.