English –
21
English
TECHNICAL SPECIFICATIONS OF PRODUCT COMPONENTS
CLB207 is manufactured by NICE S.p.A. (prov. of Treviso – Italy). Nice S.p.A., in order to improve its products, reserves the right to modify their
technical specifications at any time without prior notice. In any case, the manufacturer guarantees their functionality and fitness for the intended
purposes. Note: all technical specifications refer to a temperature of 20°C.
Control Unit
CLB207
Product type
Assembly Protection rating Dimensions / weight Control unit for 1 or 2 24V
motors for auto-
mation of automatic gates or doors, complete with radio receiver for “ECCO5...” transmitters
Technology adopted
Electronic board governed by 8-bit microcontroller with flash technology
A transformer incorporated in the control unit, but separated from the board, reduces the mains
voltage to the nominal 24 V voltage used in the whole automation system
Max. cycles frequency
30 cycles/hour
Power supply
230V (+10% -10%) 50/60Hz
Absorbed rated power
70W; on start-up power is 160W for a maximum time interval of 2s
Emergency power supply
For “PR100” buffer batteries
Motor outputs
2, for 24V
motors with nominal current of 1.1A, on start-up, maximum current is 3.5 A for a
maximum time interval of 2 s
Flashing light output
For flashing lights with 12V (maximum 21 W) bulb
ECSbus output
1 output with maximum load of 15 ECSbus units
“SbS” input
For normally open contacts (closure of the contact prompts the “Step-by-Step” command)
“STOP” input
For normally open and/or 8,2kohm constant resistance type contacts, or normally closed con-
tacts with self-learning of the “normal” status (a variation with respect to the memorised status
generates a “STOP” command)
Radio aerial input
50 ohm for RG58 or similar type cable
Max. cable length
Mains power supply: 30 m; motors outputs: 10 m; other inputs/outputs: 20 m with antenna cable
preferably shorter than 5 m (observe the warnings regarding minimum gauge and type of cables)
Ambient operating temperature
-20°C … 50°C
Assembly
Vertical, wall-mounted
Protection rating
IP44
Dimensions / weight
180 x 240 h 110 mm / 2.8 kg
Possibility of remote control
Using “ECCO5...” transmitters, the control unit is able to receive one or more of the following
commands: “Step-by-Step”, “Partial Open”, “Open Only” and “Close Only”
Compatible ECCO5... transmitters
Up to 256 if memorised in Mode 1
ECCO5... transmitter range
From 50 to 100m. This range can vary if there are obstacles or electromagnetic disturbances,
and is affected by the position of the receiving aerial incorporated in the flasher
Programmable functions
“Single cycle” or “Complete cycle” (automatic closure) operating mode
Motor speed “low” or “high”
Pause time in “complete cycle” selectable from 10, 20, 40, and 80 seconds
Type of partial opening selectable from 4 modes
Obstacle detection system sensitivity selectable on 4 levels
“Step-by-Step” command functionality selectable in 4 modes
Self-programmed functions
Self-learning of devices connected to the ECSbus output
Self-learning of type of “STOP” device (NO, NC or 8.2 kΩ resistance contact)
Self-learning of manoeuvre length for each motor
Automation autodetection with 1 or 2 motors
Summary of Contents for CLB207
Page 2: ...Fran ais...
Page 9: ...Fran ais 7 Fran ais 8 7 1 Led SAFE 3 2 4 5 mm 01 03 05 02 04 9...
Page 10: ...8 Fran ais Fran ais 6 mm x4 05 B 6 mm x4 05 A 2 1 aerial flash 2 1 06 07 08 09 02 03 04 01 10...
Page 26: ...Fran ais...
Page 33: ...English 7 English 8 7 1 Led SAFE 3 2 4 5 mm 01 03 05 02 04 9...
Page 34: ...8 English English 6 mm x4 05 B 6 mm x4 05 A 2 1 aerial flash 2 1 06 07 08 09 02 03 04 01 10...
Page 50: ......
Page 57: ...Italiano 7 Italiano 8 7 1 Led SAFE 3 2 4 5 mm 01 03 05 02 04 9...
Page 58: ...8 Italiano Italiano 6 mm x4 05 B 6 mm x4 05 A 2 1 aerial flash 2 1 06 07 08 09 02 03 04 01 10...
Page 74: ...Fran ais...
Page 81: ...Polski 7 Polski 8 7 1 Led SAFE 3 2 4 5 mm 01 03 05 02 04 9...
Page 82: ...8 Polski Polski 6 mm x4 05 B 6 mm x4 05 A 2 1 aerial flash 2 1 06 07 08 09 02 03 04 01 10...