the characteristics of the OLD one; in other words if the old one is mem-
orised in Mode 1 then the NEW one will also be memorised in Mode 1;
in this case during the memorisation phase press any one key on the
two transmitters. If the OLD radio transmitter is memorised in Mode 2
press the key with the required command on the OLD transmitter and
press the key on the NEW transmitter with which you wish to associate
the new command.
Take the two transmitters and position yourself within the action range of
the automation and follow the following steps:
01.
Press the key on the NEW radio transmitter for at least 5 s then
release it.
02.
Press the key on the OLD radio transmitter slowly 3 times.
03.
Press the key on the NEW radio transmitter slowly once.
At this point the NEW radio transmitter will be recognised by the control
unit and will take on the characteristics of the OLD one.
Repeat these steps for each new transmitter to be memorised.
9.4.4 - Deleting a radio transmitter
It is necessary to have a radio transmitter to delete it.
If the transmitter is memorised in Mode 1 one single deletion phase is suf-
ficient and at point 3 any key can be pressed. If the transmitter is memo-
rised in Mode 2 a deletion phase must be carried out for each key.
01.
Press the
P1
key
[B]
key (
fig. 22
) on the control unit and hold it
down.
02.
Wait until the
led
P1
[A]
(
fig. 22
) lights up, within three seconds.
03.
Press the key on the radio transmitter to be deleted for at least three
seconds. If deletion is successful
led
P1
will emit five quick flashes. If
led
P1
emits one slow flash it means that the deletion has not been
completed because the transmitter is not memorised.
04.
To delete other transmitters keep key
P1
pressed and repeat step 3
within 10 seconds otherwise the deletion procedure will end auto-
matically.
9.4.5 - Deleting all memorised radio transmitters
This procedure deletes all memorised transmitters.
01.
Press the
P1
key
[B]
key (
fig. 22
) on the control unit and hold it
down.
02.
Wait until the
P1
led
[A]
(
fig. 22
) lights up, then wait until it goes off,
then wait until it has flashed 3 times.
03.
Release
P1
key precisely when the
led
flashes the third time.
04.
Wait about 4s for deletion to be completed, during which the
P1
led
will emit quick flashes.
If the procedure is successful after a few moments the
led
P1
will emit 5
slow flashes.
N
M
N
M
FLASH
BUS
STOP
SbS
A
B
22
TABLE 9
1 time
“Step-by-Step” command
Commands the automation as described in table 3 (Step-by-Step function)
2 times
“Pedestrian opening” command
Causes partial opening of one or two leaves as described in table 3 (Pedestrian Opening)
3 times
“Open only” command
Causes the leaves to open (open - stop - open etc.)
4 times
“Close only” command
Causes the leaves to close (close - stop - close etc.)
5 times
“Stop” command
Halts the manoeuvre
6 times
“Apartment block Step-by-Step”
command
The command has no effect on opening, when closing the command causes the move-
ment to reverse, that is, opens the leaves
7 times
“High priority Step-by-Step” command
Works also when the automation is locked
8 times
“Pedestrian opening 2” command
Causes partial opening of leaf M2, equal to halfway
9 times
“Pedestrian opening 3” command
Causes partial opening of both the leaves, equal to halfway
10 times “Open + lock automation” command
Causes an opening manoeuvre and when this is complete, the automation is locked;
the control unit will not accept any command other than “High priority Step-by-Step” and
“Release” of the automation
11 times “Close + lock automation” command
Causes a closure manoeuvre and when this is complete, the automation is locked; the con-
trol unit will not accept any command other than “High priority Step-by-Step” and “Release”
of the automation
12 times “Lock automation” command
Causes a halt of the manoeuvre and locks the automation; the control unit will not accept
any command other than “High priority Step-by-Step” and “Release” of the automation
13 times Release automation” command
Causes automation release and reset to normal operation
Summary of Contents for CLB207
Page 2: ...Fran ais...
Page 9: ...Fran ais 7 Fran ais 8 7 1 Led SAFE 3 2 4 5 mm 01 03 05 02 04 9...
Page 10: ...8 Fran ais Fran ais 6 mm x4 05 B 6 mm x4 05 A 2 1 aerial flash 2 1 06 07 08 09 02 03 04 01 10...
Page 26: ...Fran ais...
Page 33: ...English 7 English 8 7 1 Led SAFE 3 2 4 5 mm 01 03 05 02 04 9...
Page 34: ...8 English English 6 mm x4 05 B 6 mm x4 05 A 2 1 aerial flash 2 1 06 07 08 09 02 03 04 01 10...
Page 50: ......
Page 57: ...Italiano 7 Italiano 8 7 1 Led SAFE 3 2 4 5 mm 01 03 05 02 04 9...
Page 58: ...8 Italiano Italiano 6 mm x4 05 B 6 mm x4 05 A 2 1 aerial flash 2 1 06 07 08 09 02 03 04 01 10...
Page 74: ...Fran ais...
Page 81: ...Polski 7 Polski 8 7 1 Led SAFE 3 2 4 5 mm 01 03 05 02 04 9...
Page 82: ...8 Polski Polski 6 mm x4 05 B 6 mm x4 05 A 2 1 aerial flash 2 1 06 07 08 09 02 03 04 01 10...