English –
5
English
INSTALLATION: COMPONENT ASSEMBLY AND CONNECTION
––– STEP 5 –––
5.1 - INSTALLING CLB207 CONTROL UNIT
01.
Select the installation position in an area protected against potential
impact and in the vicinity of the gate, to reduce the overall length of
the cables;
02.
Remove the cover by prying with a screwdriver on the opening at the
bottom; slide it a few centimetres and then lift it up from the bottom
(
fig. 3
);
03.
Lay the duct for routing the electric cables so that they can be insert-
ed from the lower section of the control unit;
04.
Drill a hole in the bottom of the control unit and use suitable fitting to
affix the cable passage ducts, as shown in
fig. 4
;
05.
Breach the two holes at the bottom with a screwdriver; mark the drill-
ing points using the bottom as reference (
fig. 5
);
06.
Use a percussion drill to drill the wall, with a 6 mm tip, and insert 6
mm plugs;
07.
Secure the bottom with the relative screws
[A]
;
08.
Before closing the control unit, make the electrical connections, refer-
ring to
paragraph 5.6
and to
fig. 6
;
09.
To close the control unit, position the bottom cover approximately 3
cm higher than its final position, and push it downwards until it is fully
attached, as shown in
fig. 8
.
5.2 - INSTALL AND CONNECT PH200 PHOTOCELLS (fig. 9)
• position each photocell 40/60 cm above the ground • position
them on the opposite sides of the zone to be protected • position
them as close as possible to the gate (maximum distance = 15 cm)
• a tube for passing the cables must be present in the fastening
point • orient the TX transmitter towards the central zone of the
RX receiver (allowed misalignment: maximum 5°)
For the installation procedure see
Fig. 9
.
5.3 - INSTALL AND CONNECT FL200 FLASHING INDICA-
TOR (fig. 10)
• The flashing light must be positioned near the gate in a clearly
visible position. It can be fasted to a horizontal or vertical surface.
•
For connection to the Flash terminal, no polarity needs to be observed;
instead for connection of the shielded aerial cable, it is necessary to con-
nect the cable and sheath as shown in
Fig. 6
.
Choose the most suitable position in which to install the flashing light: it
must be positioned near the gate in a clearly visible position. It can be
fasted to a horizontal or vertical surface.
For the installation procedure see
Fig. 10
.
5.4 - ELECTRICAL CONNECTION TO CONTROL UNIT
CLB207
To make the electrical connection, at very low voltage, of the various
devices, refer to
fig. 6
.
01. To connect the gearmotors:
remove the control unit cover as
shown in
fig. 3
.
02.
Loosen the cable clamp located below the gearmotor, route through
the electric cable, then tighten the cable clamp fully down (
fig. 4
).
03.
Make the electrical connections observing the colour coding shown
in
fig. 6
.
04.
Close the cover of the control unit.
At this point, make the electrical connections of the various devic-
es (see the paragraphs of the various accessories):
• The terminals have the same colour as the terminals on the correspond-
ing devices; for example the grey terminal (SbS) of the KS200KIT (optional
accessory) key-operated selector switch must be connected to the grey
terminal (SbS) of the control unit;
• No polarity is needed for virtually any of the connections; only in the
case of the shielded cable of the aerial, the central core and sheath must
be connected as shown in detail
[A]
di
fig. 6
.
Notes
-
To facilitate the hookup, you can remove the terminals as shown
in
fig. 7 - [A]
; insert the wires and then restore them to their original posi-
tions. Once the connections are complete, use cable ties to secure the
electrical cables to the appropriate fixtures
[B]
(
fig. 7
).
Summary of Contents for CLB207
Page 2: ...Fran ais...
Page 9: ...Fran ais 7 Fran ais 8 7 1 Led SAFE 3 2 4 5 mm 01 03 05 02 04 9...
Page 10: ...8 Fran ais Fran ais 6 mm x4 05 B 6 mm x4 05 A 2 1 aerial flash 2 1 06 07 08 09 02 03 04 01 10...
Page 26: ...Fran ais...
Page 33: ...English 7 English 8 7 1 Led SAFE 3 2 4 5 mm 01 03 05 02 04 9...
Page 34: ...8 English English 6 mm x4 05 B 6 mm x4 05 A 2 1 aerial flash 2 1 06 07 08 09 02 03 04 01 10...
Page 50: ......
Page 57: ...Italiano 7 Italiano 8 7 1 Led SAFE 3 2 4 5 mm 01 03 05 02 04 9...
Page 58: ...8 Italiano Italiano 6 mm x4 05 B 6 mm x4 05 A 2 1 aerial flash 2 1 06 07 08 09 02 03 04 01 10...
Page 74: ...Fran ais...
Page 81: ...Polski 7 Polski 8 7 1 Led SAFE 3 2 4 5 mm 01 03 05 02 04 9...
Page 82: ...8 Polski Polski 6 mm x4 05 B 6 mm x4 05 A 2 1 aerial flash 2 1 06 07 08 09 02 03 04 01 10...