3.95
EDH0162En1040 – 06/99
MM4005
PI — Set step of generation of pulses of synchronisation
Usage
IMM
PGM
MIP
Syntax
xxPInn
or
xxPI?
Parameters
Description
xx
[int]
— Axis number.
nn
[float]
— New value of step of generation of pulses.
?
— Read the actual step of generation of pulses of synchro-
nisation for the axis #
xx
.
Range
xx
—
1
to
4.
nn
—
2 x Coder precision
to
maximum allowed travel
.
Units
xx
— None.
nn
— Preset units in SETUP mode.
Defaults
xx
Missing: Error B.
Out of range: Error B.
Floating point: Error A.
nn
0 or missing: Stop generation of pulses.
Out of range: Error C.
Description
This command sets step of generation of pulses of synchronisation for an
axis. If
nn
is default or zero, the generation of pulses of synchronisation is
disabled.
The command can be sent at any time but it has no effect until the PS com-
mand is received.
The minimum value of step: the displacement of stage within T
base
will be
verified in PS command.
Returns
If the sign
“?”
takes place of the
nn
value, this command reportes the step
of generation of pulses of synchronisation for
xx
numbered axis. 0 means
that no pulse is generated.
Errors
A
—
Unknown message code.
B
—
Incorrect axis number.
C
—
Parameter out of limits.
Rel. Commands
PB
—
Set start position of generation of pulses of synchronisation.
PE
—
Set end position of generation of pulses of synchronisation.
Example 2PI0.1
|
Set step of pulses for axis #2 to 0.1 unit.
… |
… |
… |
2PI?
|
Actual value of PI ?
2PI0.5
|
Controller tells the actual value.
… |
… |
… |
2PS
|
Update PB, PE, PI and allow pulses.
… |
… |
… |
2PI?
|
Actual value of PI ?
2PI0.1
|
Controller tells the value.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com