- 74 -
www.NewLeader.com
(800) 363-1771
317314-C
Raven OMNiPOWER NL5000 G5
Troubleshooting
Symptom:
Reason:
Correction:
Hydraulics over-
heating
Pump failure
Flow and pressure test pump�
Too much flow
Flow test pump�
System relief
Pressure test relief (adjust or replace as
needed)� Adjust settings and speed�
Conveyor valve relief
Pressure test relief (adjust or replace as
needed)� Adjust settings and speed�
Oil cooler fan failure
see cooler fan failures�
Case drain on mono valve is
plugged�
Case drain requires zero pressure line back to
tank�
No warnings being
displayed
Warnings are only shown
when VT screen is active on
monitor
Switch from viewing map to viewing VT�
Bin level sensors not
working properly
Not enabled
Verify system was configured with bin level
sensors installed�
Bin level sensor failure
Replace sensor�
Bin level sensor harness
failure
Replace harness�
Not applying correct
rate
Incorrect settings
Verify density, swath width, gate opening,
encoder pulses, and CFR number are all
adjusted as needed�
No ground speed
Manual speed is enabled,
but set to 0
Enter correct speed or disable manual speed
AUX broadcast speed is
enabled but radar not
installed
Disable broadcast AUX speed�
Incorrect speed source is
selected
Select correct speed source�
Conveyor tensioning
incorrect
Cartridge isn’t adjusted
properly
Adjust valve to achieve correct tension�
Cartridge has failed
Replace cartridge�
Feedgate not
responding
Spinner fore / aft not
responding
Spinner left / right not
responding
Feedgate actuator sensor
failure
Replace feedgate actuator�
Feedgate harness failure
Replace feedgate harness�
PID settings incorrect
Contact New Leader product support�
Air in hydraulic system�
Perform bleed procedure� See “Controller
Operations” section for details�
Summary of Contents for Raven OMNiPOWER NL5000 G5
Page 8: ...Insert Current New Leader Warranty Warranty ...
Page 9: ...SAFETY ...
Page 28: ...INSTALLATION ...
Page 45: ... 43 Raven OMNiPOWER NL5000 G5 www NewLeader com 800 363 1771 317314 C Insert Installation ...
Page 46: ... 44 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Insert Installation ...
Page 47: ... 45 Raven OMNiPOWER NL5000 G5 www NewLeader com 800 363 1771 317314 C Insert Installation ...
Page 53: ...OPERATIONS ...
Page 66: ...MAINTENANCE ...
Page 83: ...HYDRAULICS ...
Page 90: ...CONTROLLER ...
Page 147: ...SPREAD PATTERN ...
Page 158: ...PARTS ...
Page 162: ... 154 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Mounting Body ...
Page 166: ... 158 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Subframe Subframe ...
Page 168: ... 160 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Scale Scale ...
Page 169: ... 161 Raven OMNiPOWER NL5000 G5 www NewLeader com 800 363 1771 317314 C Scale Scale ...
Page 170: ... 162 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Scale Scale ...
Page 198: ... 190 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Connection Hydraulics ...
Page 199: ... 191 Raven OMNiPOWER NL5000 G5 www NewLeader com 800 363 1771 317314 C Connection Hydraulics ...
Page 200: ... 192 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Connection Hydraulics ...
Page 232: ... 224 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Tarp ...
Page 258: ... 250 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Hydraulics MultApplier ...
Page 259: ... 251 Raven OMNiPOWER NL5000 G5 www NewLeader com 800 363 1771 317314 C Hydraulics MultApplier ...
Page 260: ... 252 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Hydraulics MultApplier ...