- 96 -
www.NewLeader.com
(800) 363-1771
317314-C
Raven OMNiPOWER NL5000 G5
NOTE:
Setting value too low can cause product control system to continually hunt for target
application rate�
Setting too high will cause excessive product application error and a delay in target rate being
reached�
• Press
to set spinners� Enter
appropriate settings:
• PWM Valve settings:
• “Monitor” - no PWM control
• “Control” - tries to maintain spinner speed at
all times regardless of available hydraulic flow.
Best for hydrostatic or CVT drives�
• “Hold” - Preserves last PWM signal to valve
when conveyor is deactivated� Best for
geared transmissions with gear pumps�
• PWM Frequency - Frequency that PWM control valve is pulsed at� Settings can be found from
valve manufacturer�
•
Zero Flow Offset - Represents maximum duty cycle sent to control valve without producing any
hydraulic flow from. Increase this number to hit target rate sooner.
IMPORTANT!
Setting Zero Flow Offset too high will cause spinners to overshoot Low Spinner Speeds and
could cause delay in reaching set speed� Adjust as needed in small increments�
• PWM Gain - Determines how aggressively control valve responds when making rate
adjustments� Higher value means more aggressive system response�
IMPORTANT!
Setting PWM Gain too high spinners will become erratic� Adjust as needed in small
increments�
• Set Conveyors by selecting each bin at bottom
of screen�
NOTE:
If using PWM valves instead of Servo
valved, select “PWM” from “Control Valve
Type” list and enter settings as per notes
on Spinner valves and test for accuracy�
Controller Operations
SERVO
Enter appropriate settings:
•
Valve Response 1 - Determines speed of servo valve when product control error exceeds
Response Threshold setting� Represents fast speed of servo valve� Decreasing value will cause
servo valve to run slower� Default setting is 40%�
• Valve Response 2 - Determines speed of servo valve when product control error is less than
Summary of Contents for Raven OMNiPOWER NL5000 G5
Page 8: ...Insert Current New Leader Warranty Warranty ...
Page 9: ...SAFETY ...
Page 28: ...INSTALLATION ...
Page 45: ... 43 Raven OMNiPOWER NL5000 G5 www NewLeader com 800 363 1771 317314 C Insert Installation ...
Page 46: ... 44 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Insert Installation ...
Page 47: ... 45 Raven OMNiPOWER NL5000 G5 www NewLeader com 800 363 1771 317314 C Insert Installation ...
Page 53: ...OPERATIONS ...
Page 66: ...MAINTENANCE ...
Page 83: ...HYDRAULICS ...
Page 90: ...CONTROLLER ...
Page 147: ...SPREAD PATTERN ...
Page 158: ...PARTS ...
Page 162: ... 154 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Mounting Body ...
Page 166: ... 158 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Subframe Subframe ...
Page 168: ... 160 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Scale Scale ...
Page 169: ... 161 Raven OMNiPOWER NL5000 G5 www NewLeader com 800 363 1771 317314 C Scale Scale ...
Page 170: ... 162 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Scale Scale ...
Page 198: ... 190 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Connection Hydraulics ...
Page 199: ... 191 Raven OMNiPOWER NL5000 G5 www NewLeader com 800 363 1771 317314 C Connection Hydraulics ...
Page 200: ... 192 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Connection Hydraulics ...
Page 232: ... 224 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Tarp ...
Page 258: ... 250 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Hydraulics MultApplier ...
Page 259: ... 251 Raven OMNiPOWER NL5000 G5 www NewLeader com 800 363 1771 317314 C Hydraulics MultApplier ...
Page 260: ... 252 www NewLeader com 800 363 1771 317314 C Raven OMNiPOWER NL5000 G5 Hydraulics MultApplier ...