ProSafe 7200 Managed Switches CLI Manual, Software Version 8.0.3
Power Over Ethernet Commands
5-8
v1.0, May 2010
no poe reset auto
This command is used to clear Autoreset mode.
poe usagethreshold
This command sets a threshold (in percentage) for the total amount of power that can be delivered
by the switch. For example, if the switch can deliver upto a max of 300 Watts, a usage threshold of
90% ensures that we allow only 270 Watts to be used for delivering power to devices. This ensures
that we never try to draw more power than the switch can provide.
When usage threshold is set, we bring down all the PD's and bring them back up. If the consumed
power is less than threshold power (in the above case, 270 Watts), then we continue powering up
the devices. If the consumed power is 269 Watts or less, we allow the next device to be powered
up.The moment consumed power goes beyond the threshold power (270 Watts), we do not allow
any other devices to power up..
no poe usagethreshold
This command will set the usage threshold to a default value.
Format
no poe reset auto {<unit>|all}
Mode
Global Config
Format
poe usagethreshold {<unit>|all} <1-99>
Mode
Global Config
Default
90
Format
no poe usagethreshold {<unit>|all}
Mode