Troubleshooting
225
10.2. System does not Boot after Initial Instal-
lation
10.2.1. Power Cord Not Plugged In
If the power supply cable is not plugged into the chassis power connector, the system cannot boot
up, even though chassis front panel LEDs and the fan may be operational. Verify that the power
connections are good.
10.2.2. Processor Issues
Boot failure situations are also caused by the following: Incompatible processor - ensure the se-
lected processor model is correct for your server board. If the processor is compatible, try remov-
ing and reinstalling the processor to ensure it is installed correctly.
Processor overheat - the system does not boot or shuts down shortly after booting.
• Ensure that the cooling fans are correctly installed and running.
• Ensure that the correct thermal interface material or the thermal grease is applied to the proces-
sor.
• Ensure that the power supply fan is running.
• Ensure that the air intakes for the fans are unobstructed.
10.2.3. Memory Issues
If you have installed incompatible memory modules, the system may not boot. Verify the memo-
ry you’ve installed has been tested with your board. If the installed memory is compatible, remove
and reinstall the memory modules. Defective memory modules may cause boot errors. To isolate a
specific memory module as defective, boot the system with just one memory module installed at a
time.
10.2.4. Monitor Issues
Monitor configurations can cause boot failure. Run through the following checklist to verify monitor
operation:
• Ensure the monitor is plugged in and turned on.
• Ensure all cables are connected properly between the monitor and the computer.
• Check the brightness and contrast controls on the monitor are not too low.
Most monitors employ indicator LEDs showing status. Refer to the monitor’s documentation to
confirm operation. If the probem still persists, try replacing the monitor or test the monitor on a dif-
ferent AC outlet/different system.
Summary of Contents for Demos R130 M2
Page 1: ...Netberg Demos R130 M2 server...
Page 2: ...Netberg Demos R130 M2 server...
Page 11: ...Netberg Demos R130 M2 server xi 9 5 Aligning the Rails 222...
Page 14: ...1 Chapter 1 Netberg Demos R130 M2 server...
Page 31: ...Netberg Demos R130 M2 server 18 On HDD failure HDD Fault Amber Off No failure detected...
Page 32: ...19 Chapter 2 Installing hardware...
Page 57: ...Installing hardware 44 Figure 2 36 Installing the Air Duct...
Page 60: ...Installing hardware 47 Figure 2 40 Connecting the Fan Assembly Cables...
Page 143: ...130 Chapter 6 Server Management Software...
Page 169: ...156 Chapter 8 Web Graphical User Interface GUI for ESMS...
Page 230: ...217 Chapter 9 Rail Kit Assembly...
Page 236: ...223 Chapter 10 Troubleshooting...