Server Management Software
150
Set Sensor Type
S/E
2Eh
O
Yes
Get Sensor Type S/E
2Fh
O
Yes
Set Sensor Read-
ing and Event
Status
S/E
30h
M
Yes
6.13.9. LAN Command
Table 6.12. LAN Commands
COMMAND
NETFN
CMD
O/M
SUPPORTED
Set LAN Config-
uration Parame-
ters*
Transport
01h
M
Yes
Get LAN Config-
uration Parame-
ters*
Transport
02h
M
Yes
Suspend BMC
ARP
Transport
03h
O
No
Get IP/UDP/RM-
CP Statistics
Transport
04h
O
No
*Parameters 9 and 25 are not supported.
6.13.10. SOL Command
Table 6.13. SOL Command
COMMAND
NETFN
CMD
O/M
SUPPORTED
SOL Activating
Transport
20h
O
No
Set SOL Configu-
ration Parameters
Transport
21h
O
Yes
Get SOL Configu-
ration Parameters
Transport
22h
O
Yes
6.13.11. PEF/PET Alerting Commands
Table 6.14. PEF/PET Alerting Commands
COMMAND
NETFN
CMD
O/M
SUPPORTED
Get PEF Capabil-
ities
S/E
10h
M
Yes
Arm PEF Post-
pone Timer
S/E
11h
M
Yes
Set PEF Configu-
ration Parameters
S/E
12h
M
Yes
Summary of Contents for Demos R130 M2
Page 1: ...Netberg Demos R130 M2 server...
Page 2: ...Netberg Demos R130 M2 server...
Page 11: ...Netberg Demos R130 M2 server xi 9 5 Aligning the Rails 222...
Page 14: ...1 Chapter 1 Netberg Demos R130 M2 server...
Page 31: ...Netberg Demos R130 M2 server 18 On HDD failure HDD Fault Amber Off No failure detected...
Page 32: ...19 Chapter 2 Installing hardware...
Page 57: ...Installing hardware 44 Figure 2 36 Installing the Air Duct...
Page 60: ...Installing hardware 47 Figure 2 40 Connecting the Fan Assembly Cables...
Page 143: ...130 Chapter 6 Server Management Software...
Page 169: ...156 Chapter 8 Web Graphical User Interface GUI for ESMS...
Page 230: ...217 Chapter 9 Rail Kit Assembly...
Page 236: ...223 Chapter 10 Troubleshooting...