101-000 -56- Users Manual
IDTeck – iCON 1 DOOR ACCESS CONTROLLER
☞
“SCHEDULE ERROR” message shows when RFID card is read.
Cause
Error in RFID card registration, time schedule setting or the system itself.
Solution
1. If the unit has been properly operating before, there has been electric shock that has damaged
internal memory and data. Please initialize the unit as instructed in the manual.
2. Check if ID information is put incorrectly during its registration.
* Register ID again checking the following points.
- In order to restrict access of the user for specific time zones as instructed in the manual,
register time schedule in advance and apply the time schedule code (1~10) in the registration
of the user ID.
- In order to allow the user to access at all times put “00”.
3. Use software for time schedule setting in case it is connected to PC as the software manual.
4. If the trouble remains after checking the above, contact a designated service center.
☞
“ACCESS DOOR ERR” message shows when the RF ID card is read.
Cause
Incorrect user setting or false of internal circuit.
Solution
1. If the unit was operating properly before, there has been an electric shock that has damaged
internal memory and data. Please initialize the unit as instructed in the manual.
2. Check if ID information is put incorrectly during its registration.
* Register the ID again checking the following points.
- Since the controller has two reader ports, define “RD” – door for the user to be allowed to
access. Readerv1 only: “1”, Reader 2 only: “2”, Reader 1 & 2 both: “3”
- If RD is set as “1”, only when the card is read at reader 1, the door opens but not at reader 2.
If it is read at reader 2, “ACCESS DOOR ERROR” message shows.
- If RD is set as “2”, only when the card is read at reader 2, the door opens but not at reader 1.
If it is read at reader 1, “ACCESS DOOR ERROR” message shows.
- If RD is set as “3”, reader 1 & 2 both opens each door.
3. Use software for time schedule setting in case it is connected to PC as the software manual.
4. If the trouble remains after checking the above, contact a designated service center.
Summary of Contents for IDTECK iCON100
Page 1: ...IDTeck iCON100 Access Controller Rev V1 0 USER S MANUAL ...
Page 38: ...101 000 38 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER 9 2 SETUP MENU F2 ...
Page 43: ...101 000 43 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER 9 3 SETUP MENU F3 ...
Page 48: ...101 000 48 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER 9 4 SETUP MENU F4 ...
Page 60: ...101 000 60 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER ...