101-000 -29- Users Manual
IDTeck – iCON 1 DOOR ACCESS CONTROLLER
2. PW [____]: PW is the password which can be used to access the doors where you install a
proximity and Keypad Reader and setup the RF + Password operating mode. But regardless of the
operating mode, it is necessary to enter a default password (0000) in the PW [____] field when you
register an ID.
3. TS__: TS is the Time Schedule code (00-10). When you present the card to the reader then the
cardholder is only allowed access to the door during the Time Schedule code entered. To control the
accessible Time Schedule for each cardholder, you must setup the Time Schedules first and enter the
Time Schedule code here. If you want to access the door anytime for the cardholder then enter the
default Time Schedule code '00' for the value.
4. RD__: RD is Reader Usage codes for the cardholder. If you put a ‘1’ for RD then Reader #1 is
accessible and if you put ‘0’ for RD then the cardholder can not get access through any reader, and
the NESS - iCON100 generates an error message “Access Door Error” and displays it on the LCD. To
get access through all Readers, you have to input ‘3’ value for RD.
8. OPERATION
8.1 NORMAL OPERATION
Power On
When the power is applied to the NESS iCON100, then LED 3 is turned on.
Registered Card Reading
When a registered card (or PIN) is read, the Door (Relay #1) will open for 3 seconds (Default) with
the LED #4 on.
Exit Button
To request exit from the inside, an Exit Button (or an Exit Reader) can be used.
The Door (Relay #1) will open for 3 seconds with the LED #4 on.
Alarms
When an unregistered card is read, the access is denied and the alarm (Relay #2) will be activated for
3 seconds with the LED #5 will come on.
8.2 DEFAULT SETTING
When you operate the NESS - iCON100 for the first time or you initialize the NESS - iCON100, the
controller will setup all default values (factory settings). You can change the settings for your desired
application.
Please refer to the APPENDIX for the default setting values.
Summary of Contents for IDTECK iCON100
Page 1: ...IDTeck iCON100 Access Controller Rev V1 0 USER S MANUAL ...
Page 38: ...101 000 38 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER 9 2 SETUP MENU F2 ...
Page 43: ...101 000 43 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER 9 3 SETUP MENU F3 ...
Page 48: ...101 000 48 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER 9 4 SETUP MENU F4 ...
Page 60: ...101 000 60 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER ...