3.3 OPTIONAL ACCESSORIES
3.3.1 LCD DISPLAY MODULE
You can connect an optional LCD display module to the NESS - iCON100 main control board. With
a keypad, this allows you to setup all functions on the NESS - iCON100 manually.
3.3.2 KEYPAD
You can connect an optional keypad to the NESS - iCON100 main control board. With an LCD
display module you can setup all functions to the NESS - iCON100 manually.
4. INSTALLATION REQUIREMENTS
Installing the
NESS - iCON100
is a relatively easy task. It can be installed with common hand tools and
readily available communications wire. This section provides information about wiring, wire runs and other
information to make the installation quick and easy.
4.1 CHECK POINTS BEFORE INSTALLATION
4.1.1 CABLE / WIRE
Good electrical connections will minimize line losses and prevent damage to the
NESS - iCON100
control electronics. Use good quality wire that’s a proper thickness with durable insulation such as
vinyl or PVC. It may be faster and much economical to run multiple, twisted pair cable rather than
individual pairs. The following cable and wire thickness from the Belden Master Catalog 885 are
adequate for most
NESS - iCON100
applications. These are offered as a reference only.
Belden No. 9745 3 twisted pairs, 22 AWG, 7/30 stranded, unshielded, PVC insulation and jacket,
14.7 ohms/1000 feet (about 300meter).
Belden No. 9750 3 twisted pairs, 20 AWG, 10/30 stranded, unshielded, PVC insulation and jacket,
10.3 ohms/1000 feet (about 300meter).
Belden No. 8303
3 twisted pairs, 22 AWG, 7/30 stranded, shielded, overall foil/braid shield, PVC
insulation and jacket, 14.7 ohms/1000 feet (about 300meter).
CONDUIT
The
NESS - iCON100
does not normally require conduit. However, some locations may require
conduit for wire protection. Check installation requirements and specifications for your site.
COMMUNICATIONS WIRING
NESS -iCON
communication is required for using twisted pair wires.
CAUTION:
Distance can be reduced by surroundings.
Summary of Contents for IDTECK iCON100
Page 1: ...IDTeck iCON100 Access Controller Rev V1 0 USER S MANUAL ...
Page 38: ...101 000 38 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER 9 2 SETUP MENU F2 ...
Page 43: ...101 000 43 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER 9 3 SETUP MENU F3 ...
Page 48: ...101 000 48 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER 9 4 SETUP MENU F4 ...
Page 60: ...101 000 60 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER ...