101-000 -54- Users Manual
IDTeck – iCON 1 DOOR ACCESS CONTROLLER
☞
A valid card became unregistered after batch-downloading Ids from PC.
Cause
Wrong procedure during download, or a component defect.
Solution
1.
The card ID might be registered only to the controller and not registered in the PC. During the
process of downloading IDs, the NESS iCON100 will first erase the ID memory of the unit,
therefore if the IDs from the PC didn’t contain the card ID, this can happen.
2.
Check whether the card ID is registered in PC
3.
If not, please register the number and try downloading again.
4.
If the trouble remains after the procedure above, contact a designated service center.
☞
Doesn’t enter the Setup Mode after entering the Master ID “00000000”.
Cause
The Master ID might be changed or components are defective.
Solution
1. Try changing the Master ID through the application S/W. (It’ll be changed to “00000000”.)
2. When it is not feasible, initialize the unit as followings.
- In power-on, put off ->on the #8 DIPswitch.
- Check if the LCD shows message of “Turn OFF DIP.8” “Press Any Key…”
- Put back DIPswitch 8 from ON to OFF.
- Reset the power (turn it off and on).
* Aware that all the setting values will be put back to the default value and data memory
be cleared.
(ID data clear/Event data clear/ Time Schedule data clear etc.)
3. If the trouble remains after the procedure above, contact a designated service center.
☞
No problem with accessing by cards, but cannot access with the PIN input.
Cause
An error in Setup or possible component defect.
Solution
1. Check whether a beep sound is generated when you press a key.
When it is, the problem may be an error in setup. Proceed as following.
- Enter the Master ID (“00000000” default) to enter the Setup mode.
- Press the <F1> key.
- [MODE SELECTION] will appear on the LCD, then use the <6> key to choose
[RF_PIN_INPUT] and select ‘Enable’ as wanted.
2. When there is no beep sound or already enabled Key-in functions, contact a designated service
center.
Summary of Contents for IDTECK iCON100
Page 1: ...IDTeck iCON100 Access Controller Rev V1 0 USER S MANUAL ...
Page 38: ...101 000 38 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER 9 2 SETUP MENU F2 ...
Page 43: ...101 000 43 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER 9 3 SETUP MENU F3 ...
Page 48: ...101 000 48 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER 9 4 SETUP MENU F4 ...
Page 60: ...101 000 60 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER ...