![Ness IDTECK iCON100 User Manual Download Page 42](http://html.mh-extra.com/html/ness/idteck-icon100/idteck-icon100_user-manual_1669320042.webp)
101-000 -42- Users Manual
IDTeck – iCON 1 DOOR ACCESS CONTROLLER
9.2.5 READER TIME SCHEDULE SETTING
9.2.6 OUTPUT TIME UNIT SETTING
☞
. If you setup RF+PASSWORD operating mode (Refer to MODE
SELECTION), you can apply a Time Schedule for MODE
INDEX. During the time period of Time Code in the T/S, Reader
#1 will operate in RF ONLY mode. And the rest of time period,
Reader #1 will operate in RF+PASSWORD mode.
To apply this function, you have to setup Time Schedules (T/S)
and Holiday Schedules (H/S).
Select MODE INDEX then press the <ENT> key. Enter a 2 digit
T/S index (‘00’ ~ ‘10’) then press the <ENT> key to apply it.
MODE INDEX
00
MODE INDEX
00
☞
. This menu is to define the time unit of 5 output ports.
1 sec: define the time of the output by seconds in the in/out define.
100 ms: define the time of the output by 0.1 second (100ms) in the
in/out define setup.
Ex) In order to have the relay #1(Out #1) operate for 3 seconds,
responding to the exit button input, set it as follows.
- Define 1 Exit & Relay as “03” in IN/OUT define
- Define the OUTPUT TIME SET as second.
Ex) In order to have the relay #1(Out #1) operate for 0.3 second,
responding to the exit button input, set it as follows.
- Define 1 Exit & Relay as “03” in IN/OUT define
- Define the OUTPUT TIME SET as 100ms.
OUTPUT TIME SET
1sec
OUTPUT TIME SET
-> 100ms
Summary of Contents for IDTECK iCON100
Page 1: ...IDTeck iCON100 Access Controller Rev V1 0 USER S MANUAL ...
Page 38: ...101 000 38 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER 9 2 SETUP MENU F2 ...
Page 43: ...101 000 43 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER 9 3 SETUP MENU F3 ...
Page 48: ...101 000 48 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER 9 4 SETUP MENU F4 ...
Page 60: ...101 000 60 Users Manual IDTeck iCON 1 DOOR ACCESS CONTROLLER ...