FlexPAK 800/1000 DX
43
EN
7.2.7
ClenCyl
Menu for setting the opening and closing times for the FCV cleaning cycle. The FCV cleaning
cycle is repeated 3 times when filter cleaning is activated for both manual and automatic filter
cleaning. If TH is set to 0, no filter cleaning is performed.
NOTE!
If PSIFC is activated, ‘Switch=On’, TH cannot be set to 0. See Section ‘7.3.7 PSIFC’.
The default time for a complete cleaning cycle is 15 seconds. 3(TH+TL)=3*5=15 where
TH=02:00s and TL=03:00s.
TH=02:00s: The default time for the FCV to be open.
TL=03:00s: The default time for the FCV to be closed. The minimum setting is 3 seconds.
Ta=00:00: The elapsed time since the FCV cleaning cycle was activated.
ClenCyl
TH = 02:00s
TL = 03:00s
Ta = 00:00
ESC
OK
TH=
TL=
7.3
Parameter settings: Accessories, customer connections
7.3.1
FlushTmr
Menu for automatic flushing of the duct system with the interval timer. FlushTmr activates
FlushCy1 and FlushCy2. FlushTmr is deactivated if PSCFlush is activated ‘Switch=On’, see
Section ‘7.3.8 PSCFlush’.
T=60:00m: Time between flushings. The default setting is 60 minutes.
Ta=00:00: The elapsed time since the flushing cycle started.
FlushTmr
T=60:00m
Ta=00:00
ESC
OK
T=
NOTE!
For a description of the following displays please see the ‘Installation and service
manual’.
7.3.2
MFDPS-FC
MFDPS-FC
T=01:00m
Ta=00:00
ESC
OK
T=
7.3.3
MFDPS-Wr
MFDPS-Wr
T=10:00m
Ta=00:00
ESC
OK
T=
Summary of Contents for FlexPAK 1000 DX
Page 2: ...FlexPAK 800 1000 DX 2 ...
Page 9: ...FlexPAK 800 1000 DX 9 A B C 4A 3 13 12 10 9 7 8 2 1 3 4 6 5 11 ...
Page 10: ...FlexPAK 800 1000 DX 10 4C 4B 11 7 8 9 12 13 16 15 14 17 18 19 20 21 10 ...
Page 14: ...FlexPAK 800 1000 DX 14 11 12 14 13 ...
Page 15: ...FlexPAK 800 1000 DX 15 1 5m 59 A B C 16 17 15 Min 2 1m 83 A A A A C ...
Page 17: ...FlexPAK 800 1000 DX 17 19 Circuit Diagram FlexPAK 800 1000 Digital I O Extension Modul DU2 ...
Page 18: ...FlexPAK 800 1000 DX 18 20 Circuit Diagram FlexPAK 800 1000 PT100 Extension Module DU3 ...
Page 20: ...FlexPAK 800 1000 DX 20 22 ...
Page 545: ...www nederman com ...