FlexPAK 800/1000 DX
EN
36
•
Hi Vacuum
•
Exhaust Air Temp High
•
Auto Cleaning Cycle To Intermittent Filter Heavy Clogged Check Filter
•
Bag Replacement Switch Time Out
•
Control Filter Clogged
•
Error! TVFD Gate
•
TVFD Error! Upper Slide Not Closed
•
TVFD Error! Upper Slide Not Open
•
TVFD Error! Lower Slide Not Closed
•
TVFD Error! Lower Slide Not Open
•
TVFD Error! Slides In Open Position
6.4.1
Frequency Conv Alarm
The frequency converter has detected a problem and has put the unit into Off mode. The following
list shows the most common problems:
•
Connection problem to main power supply.
•
Motor cable problem.
•
Power supply fault.
•
There is a problem with the frequency converter.
Frequency
Conv Alarm
Reset OK==>
ESC
OK
6.4.2
PTC Detect Hi Motor Temp Unit Shut Down
The frequency converter has detected that the PTC sensors in the motor have reached the
maximum temperature for the unit (140°C), so the unit has been put into Off mode.
PTC Detect Hi Motor Temp
Unit Shut Down
Reset OK==>
ESC
OK
6.4.3
Hi Vacuum
The maximum vacuum level has been activated, and the delay time for the vacuum alarm has
elapsed. Press ‘OK’ to reset the alarm.
Hi Vacuum
Level -36kPa
Reset OK==>
ESC
OK
.
Summary of Contents for FlexPAK 1000 DX
Page 2: ...FlexPAK 800 1000 DX 2 ...
Page 9: ...FlexPAK 800 1000 DX 9 A B C 4A 3 13 12 10 9 7 8 2 1 3 4 6 5 11 ...
Page 10: ...FlexPAK 800 1000 DX 10 4C 4B 11 7 8 9 12 13 16 15 14 17 18 19 20 21 10 ...
Page 14: ...FlexPAK 800 1000 DX 14 11 12 14 13 ...
Page 15: ...FlexPAK 800 1000 DX 15 1 5m 59 A B C 16 17 15 Min 2 1m 83 A A A A C ...
Page 17: ...FlexPAK 800 1000 DX 17 19 Circuit Diagram FlexPAK 800 1000 Digital I O Extension Modul DU2 ...
Page 18: ...FlexPAK 800 1000 DX 18 20 Circuit Diagram FlexPAK 800 1000 PT100 Extension Module DU3 ...
Page 20: ...FlexPAK 800 1000 DX 20 22 ...
Page 545: ...www nederman com ...