E-PAK 150 DX/300 DX/500 DX
EN
30
Motor
power
(kW/hp)
Voltage
and
frequency
(V)/(Hz)
Nom.
current
(A)
F1
Recom.
mains
fuses,
slow (A)
F2 &
F3,
slow
(A)
F4,
slow
(A)
F5 &
F6,
fast
(A)
S1F Over-
load relay
setting
(A)
Min.
cable
area to
motor
(mm
2
) Z
Cable
area
inside
starter
(mm
2
) V
Cable
area
inside
starter
(mm
2
) X
3.45/5
230/60
12.6
25
6
4
1
12.6
2.5
2.5
2.5
3.45/5
440/60
7.7
15
6
4
1
7.7
2.5
2.5
2.5
3.45/5
460/60
7.3
15
6
4
1
7.3
2.5
2.5
2.5
3.45/5
575/60
4.95
15
6
4
1
4.95
2.5
2.5
2.5
6
Main components
Figure 5 shows the main components of E-PAK 150 DX/300 DX/500 DX.
These are as follows:
1.
Filter cleaning device.
2.
Control filter.
3.
Start and control unit and control panel.
4.
Dust collector.
5.
Vacuum limiting valve.
6.
Thermal switch, 125 °C (257 °F), with automatic reset.
7.
High-pressure side channel fan.
8.
Pressure switch.
9.
Outlet silencer.
10.
Outlet.
11.
Main filter.
12.
Explosion relief panel (not on E-PAK 150 DX/300 DX/500 DX intended
for a suppression system).
NOTE!
The explosion relief panel is to be handled with great care. Never
bend the membrane or frame.
13.
Flanged inlet.
14.
Collector bin with antistatic plastic bag.
NOTE!
Never use the unit without the antistatic plastic bag! Use
Nederman original bags only.
15.
Acoustic enclosure.
16.
Detection device (suppression system only), see Figure 5b.
17.
Action element (suppression system only), see Figure 5b.
6.1
Start and control unit
E-PAK 150 DX/300 DX/500 DX has a start and control unit, see Figure 10. For
information about the different terminals, see the terminal connection diagrams
in Figure 23 (E-PAK 150 DX) and Figure 24 (E-PAK 300 DX/500 DX).
NOTE!
E-PAK 150 DX has a simplified start and control unit without Y/D
connectors and Y/D timer.
Summary of Contents for E-PAK 150 DX
Page 2: ...E PAK 150 DX 300 DX 500 DX 2 ...
Page 5: ...E PAK 150 DX 300 DX 500 DX 5 2 800 31 5 150 6 3 ...
Page 6: ...E PAK 150 DX 300 DX 500 DX 6 4 2 3 4 1 ...
Page 7: ...E PAK 150 DX 300 DX 500 DX 7 5 5 2 3 6 7 8 4 9 10 1 11 12 13 15 14 5b 16 17 ...
Page 9: ...E PAK 150 DX 300 DX 500 DX 9 8 1 2 3 5 6 7 8 4 9 10 11 A ...
Page 10: ...E PAK 150 DX 300 DX 500 DX 10 9 10 1 13 14 15 3 5 6 7 4 16 8 9 10 11 1 2 3 5 4 2 17 12 ...
Page 11: ...E PAK 150 DX 300 DX 500 DX 11 0 I RESET MANUAL START MANUAL FILTER CLEANING 11 12 13 ...
Page 12: ...E PAK 150 DX 300 DX 500 DX 12 15 16 17 18 14 ...
Page 13: ...E PAK 150 DX 300 DX 500 DX 13 19 E PAK 150 DX ...
Page 14: ...E PAK 150 DX 300 DX 500 DX 14 20 E PAK 300 DX 500 DX ...
Page 15: ...E PAK 150 DX 300 DX 500 DX 15 21 E PAK 150 DX ...
Page 16: ...E PAK 150 DX 300 DX 500 DX 16 22 E PAK 300 DX 500 DX ...
Page 17: ...E PAK 150 DX 300 DX 500 DX 17 23 ...
Page 18: ...E PAK 150 DX 300 DX 500 DX 18 24 1 2 4 3 ...
Page 19: ...E PAK 150 DX 300 DX 500 DX 19 25 26 ...
Page 20: ...E PAK 150 DX 300 DX 500 DX 20 27 E PAK 500 DX E PAK 300 DX E PAK 150 DX ...
Page 84: ...E PAK 150 DX 300 DX 500 DX CS 84 ...
Page 150: ...E PAK 150 DX 300 DX 500 DX DE 150 ...
Page 184: ...E PAK 150 DX 300 DX 500 DX ES 184 ...
Page 250: ...E PAK 150 DX 300 DX 500 DX FR 250 ...
Page 348: ...E PAK 150 DX 300 DX 500 DX NL 348 ...
Page 450: ...E PAK 150 DX 300 DX 500 DX PT 450 ...
Page 484: ...E PAK 150 DX 300 DX 500 DX RU 484 ...
Page 546: ...E PAK 150 DX 300 DX 500 DX ZH 546 ...
Page 547: ......
Page 548: ...www nederman com ...