– 51 –
CHAPTER 2
Operations of SV8500 Server
3.4 Initialization by INIT key Operation (EMA card)
The following initialization type is available.
•
Non Load Initial
All on-going calls will be disconnected. The system will be rebooted by using program and office data that
are in the MEM.
STEP 1
Identify which system of CPU is in operation. The following shows an example when the system
is operating by CPU #0.
STEP 2
Press “INIT” key on the EMA card to start Non Load Initial.
STEP 3
Check the lamp indications on the EMA card.
STEP 4
Set the current date and time from the PCPro. (Refer to
STEP 5
Release the indicated alarm. (Refer to
Lamp Layout on EMA Card (when CPU #0 is active)
Lamp (Color)
Status
PWR (Green)
On
SYS ALM (Red)
Off
LINK (Green)
On
ACT (Green)
On
ALM (Red)
Off
Lamp (Color)
Status
PWR (Green)
On
LINK (Green)
On
ACT (Green)
On
SYS ALM (Red)
On
[MEM]
- Program
- Office Data
Initialization
PWR
SYS
ALM
SYS 1
MB
(SUB)
SYS
LOCK
SYS
SEL
PFT
LINK
ACT
ALM
INIT
PBI No.
SYS 0
1
2
1
2
SW00
SW01
ON
0
1
PWR
SYS
ALM
SYS 1
MB
(SUB)
ON
0
1
SYS
LOCK
SYS
SEL
PFT
LINK
ACT
ALM
INIT
PBI No.
SYS 0
1
2
1
2
SW00
SW01
INIT key
Summary of Contents for SV8500
Page 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Page 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Page 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Page 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Page 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Page 973: ......
Page 974: ...Printed in Japan 0901 020...
Page 975: ......