– 617 –
CHAPTER 5
Operation Procedure for System with PIR
4.4.1
Check Point (1/2)
Confirm the data shown below when service features cannot be assigned or service cannot be operated:
(1) Confirm that line capacity of physical PIR and virtual PIR is set correctly.
(2) Confirm that value of ASYD command to display LP mounting status is assigned as below.
•
ASYD, SYS1, INDEX198=33
•
ASYD, SYS1, INDEX199=33
(3) Compare the status of “virtual PIR mounting information” with “physical/virtual PIR line capacity” dis-
played. Data is assigned as below in this system.
•
ASYD, SYS1, INDEX556=F0
•
ASYD, SYS1, INDEX557=FF
(4) Confirm that all units are properly mounted by using the AUNT command.