– 110 –
CHAPTER 2
Operations of SV8500 Server
Changeover of PLO (4-IMG)
PLO can be switched over independently of Speech Path System.
Note:
When operating MB key, ten seconds interval is required between MB key ON and OFF.
Changeover of Switching Block (4-IMG)
TYPE
OPERATIONS
REMARKS
Changeover by key opera-
tion
- Set MB key upward on the ACT PLO card.
- Make sure that ACT lamp goes off on the card.
- Return MB key downward on the card.
Note
- OPE lamp goes off when MB key is set upward on the
PLO card.
- OPE lamp lights green on the mate PLO card.
Target Cards for Manual System Changeover of PLO (4-IMG)
MODULE
SLOT
NUMBER
CIRCUIT CARD
TARGET CARD LOCATION
TSWR
14/15
PLO
(PH-CK16-D, etc)
Improper key operations may result in a system down. Operate the related keys with extreme
care.
WARNING
Voice calls are not be affected by PLO changeover. However, bit errors may occur on data
lines.
WARNING
FANU
TSWR
SV8500 Server
14 15
PLO0
PL
O
1
Summary of Contents for SV8500
Page 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Page 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Page 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Page 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Page 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Page 973: ......
Page 974: ...Printed in Japan 0901 020...
Page 975: ......