Operation Procedure for System with PIR
8
Detection of Release at the
time of Outgoing
Connection
• Loop System
Detection of polarity reversal across tip and
ring.
• E&M System
Detection of Release Signal (ground or
–48V) on E lead.
608 milliseconds (standard)
Timing can be assigned using the
ARTD command.
Table 5-5 Timings for Senders
ITEMS FOR STATUS
SUPERVISION
CONDITIONS FOR SUPERVISION
TIMING SPECIFICATIONS
1
Sender Acknowledge Wait
Timer
Timing limit for waiting to receive connection
acknowledgement signal from the opposite
office after seizing the opposite office.
4 seconds (standard)
Timing can be assigned using the
ASYD, SYS1, INDEX 130 command.
2
Sender Prepause Timer
Time from sender seizure until sending of the
1st digit where connection acknowledgment is
made by interface with the opposite office.
DP: 3 seconds (standard)
PB: 2.5 seconds (standard)
Timing can be assigned using the
ASYD, SYS1, INDEX 131 command.
3
Sender Inter-digit Timer
Inter-digit timing for the numbers sent out by
the sender.
• For DP
10 pps: 860 milliseconds
(standard)
20 pps: 460 milliseconds
(standard)
Timing can be assigned using the
ASYD, SYS1, INDEX. 132
command.
• For PB
60/120 milliseconds (selected by
ONSG of ARTD command.)
Timing can be changed using the
ASYD, SYS1, INDEX 133
command.
ITEMS FOR STATUS
SUPERVISION
CONDITIONS FOR SUPERVISION
TIMING SPECIFICATIONS
Summary of Contents for SV8500
Page 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Page 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Page 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Page 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Page 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Page 973: ......
Page 974: ...Printed in Japan 0901 020...
Page 975: ......