CHAPTER 5
Operation Procedure for System with PIR
1.3
Replacement Procedure of SDT Card and Optical Fiber Cable
This section explains how to replace SDT (PA-SDTA/PA-SDTB) card and the optical
fiber cables that are connected to SDT card.
1.3.1
How to Replace SDT (PS-SDTA/PA-SDTB)
[Start]
STEP 1
Set P-SW key - 4 (MBR) to ON position on the PA-SDTA card to be replaced.
When the card is provided in dual configuration, do this for both cards in the order of STBY - ACT.
•
ACT lamp goes OFF.
•
New call attempt will be rejected. However, already established calls can be maintained.
•
When having connection link, it will be left connected.
STEP 2
Use SPTS command to see if there is any active call on the card.
When it is found, wait a while, and try again until the card has no active call.
STEP 3
Turn ON (upward) MB key on the PA-SDTA card.
When the card is provided in dual configuration, do this for both cards in the order of STBY - ACT.
•
OPE lamp changes color to red.
•
Active calls will be placed in no-tone-state.
•
When having connection link, it will be dropped in a few seconds.
STEP 4
Turn ON (upward) MB key on the PA-SDTB card.
•
OPE lamp changes color to red.
•
Active calls on the card will be disconnected.
•
When having connection link, Nailed-down connection between FCH (PA-FCH) and SDT (PA-
SDTB) will be disconnected.
STEP 5
Disconnect MT24 from the PA-SDTB circuit card. Remove the flat cables from the front con-
nectors, I/O and PCM, on both PA-SDTA and PA-SDTB cards.
STEP 6
Remove the PA-SDTA and PA-SDTB.
STEP 7
Referring to the removed cards, perform the switch settings on the new cards.
STEP 8
Make sure that MB key on the new card is set to UP position. Set Switch 4 of P-SW key must
be set to ON position for PA-SDTA.
STEP 9
Insert the new PA-SDTA and PA-SDTB to the slots of the PIR.
•
OPE lamp lights red on the new cards.
STEP 10 Connect the disconnected flat cables to the connectors on the new card and other PA-SDTA/PA-
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
Summary of Contents for SV8500
Page 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Page 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Page 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Page 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Page 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Page 973: ......
Page 974: ...Printed in Japan 0901 020...
Page 975: ......