– 73 –
CHAPTER 2
Operations of SV8500 Server
•
CPU Replacement Procedure for CPU Dual Configuration
Replacement procedure explained here assumes the following scenario as an example:
•
CPU card (#1) must be replaced
•
CPU card (#1) is operating as ACT
Therefore, in the following explanation, replace #1 with #0 as needed when performing this procedure on the
actual system.
Note:
When the system is CPU-dual configuration, system shutdown is not necessary for CPU replacement.
[Start]
STEP 1
Make sure the CPU to be replaced is placed in STBY mode.
•
“ACT” lamp of “SYS0” side lights green: CPU card #0 is in ACT mode.
•
“ACT” lamp of “SYS1” side lights green: CPU card #1 is in ACT mode.
STEP 2
If the CPU to be replaced is in ACT mode, place it in STBY mode. Otherwise, start from
.
•
Use CMOD command from PCPro.
Note:
MODE switch - 4 is Make Busy Request (MBR) key. CPU ACT/STBY can be switched by this switch. See
“
” - “
CPU Changeover by Key Operation”
for more details.
STEP 3
Make sure the CPU to be replaced is placed in STBY mode.
•
“ACT” lamp on the EMA card is changed? (In this example, “SYS0: ACT” lamp lights green.)
STEP 4
Lock the ACT-side CPU card to ACT. (In this example, set CPU card #0 always ACT.)
•
Select ACT-side CPU by SW01-2 (SYS SEL) on EMA card. (In this example, downward.)
•
Lock CPU ACT/STBY by SW01-1 (SYS LOCK) on EMA card: upward
Note:
CPU ACT/STBY can be locked so that CPU ACT/STBY switchover may not take place during CPU card
replacement.
Note:
SW01-02 (SYS SEL) setting shown above is an example, by which CPU card #0 is locked to ACT. The
setting may vary depending on the actual system.
STEP 5
Turn off the STBY side CPU card.
<By PCPro Tools (recommended)>
•
On the initial screen, select “System Control” radio button.
•
Select an appropriate System Side (System 0 or System 1).
•
Click “Execute” button.
Summary of Contents for SV8500
Page 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Page 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Page 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Page 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Page 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Page 973: ......
Page 974: ...Printed in Japan 0901 020...
Page 975: ......