– 224 –
CHAPTER 3
System Messages
Scan Data 1: Current Status of PLO
card
Scan Data 2: Current Status of PLO
card
b7
b6
b5
b4
b3
b2
b1
b0
b7
b4
b1
b0
b0:
Clock status at time of detection
0/1 = STBY/ACT
b1:
Circuit Card status at time of detection
0/1 = PLO synchronizing/PLO self running or drift abnormal
b2:
0/1 = -/Input clock down
b3, b4: Route of Input clock
b5:
0/1 = -/PLO input all down
b6:
0/1 = -/PLO output down
b7:
0/1 = -/Drifting
b4
b3
DCS INPUT ROUTE
ROUTE OF INPUT
CLOCK
0
0
0
0
0
1
1
1
1
0
-
2
1
1
-
3
4
b0:
0/1 = -/Five milliseconds Burst Clock down
b1:
0/1 = -/Frame Synchronization from SYNC card is down
b4:
0/1 = -/Internal OSC clock down
5
Summary of Contents for SV8500
Page 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Page 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Page 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Page 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Page 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Page 973: ......
Page 974: ...Printed in Japan 0901 020...