– 12 –
CHAPTER 1
General
•
Proceed with judgment as to whether the fault status coincides with the indicated status, following
the sequence beginning from START.
•
How to proceed with the diagnosis work is explained in Figure 1-9.
STEP 1
Determine whether the fault coincides with the fault status (1) in Figure 1-9.
STEP 2
If the fault status does coincide, the fault is indicated by (2). Repair the fault by referring to the
relevant section in Chapter 4. Otherwise, proceed to (3).
STEP 3
Perform the work indicated by (3). The result of the work (3) is broken down as indicated by (4).
STEP 4
Determine whether the result of work (3) coincides with the status indicated by (5). If so, the
fault(s) is/are indicated either by (6) or by (7). If not, proceed to the next Step.
STEP 5
Perform the work indicated by (8), and if the result of the work is the same as the status indicat-
ed, the fault is indicated by (9). If the fault repair work indicated by (9) affects another normal
line, recheck the work as indicated by (10).
(b) Fault Repair Procedure
A fault repair procedure is explained by means of TREE format in Chapter 4. The following explains
how to follow the TREE format and proceed with designated work. See Figure 1-10.
•
Begin from START and proceed with the necessary repair work following the sequence.
•
When a faulty circuit card (or circuit cards) is suspected, replace the faulty circuit card with a spare
in accordance with the work procedure pertaining to that specific circuit card.
STEP 6
Replace the circuit card indicated by (A) with a spare and check it. Perform the detailed work
as per (B). If the fault status is beyond repair, proceed to the next step.
STEP 7
If the range of the fault or the system configuration is as indicated by (C), perform a check as
indicated by (D). If the fault status is beyond repair, proceed to the next step.
STEP 8
Replace the circuit card indicated by (E) with a spare and check it. The detailed procedure indi-
cated by (G) varies with the system configuration indicated by (F).
Summary of Contents for SV8500
Page 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Page 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Page 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Page 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Page 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Page 973: ......
Page 974: ...Printed in Japan 0901 020...
Page 975: ......