– 576 –
CHAPTER 5
Operation Procedure for System with PIR
2.4
Replacement Procedure of CF Card
Always backup the current program and office data stored in CF card before replacing
the CF card.
[Start]
STEP 1
Backup the office data stored in CF card and copy it into a reliable storage device.
STEP 2
Write in the program to the new CF card by referring to Installation Manual. Also, write in the
office data stored in the storage device such as a hard disk of a PC.
STEP 3
Shutdown the system, referring to “
Initialization by Turning OFF and ON the System
STEP 4
Take out the fault CF card and insert the new CF card in which program and office data have
been written.
STEP 5
Turn ON the system again, referring to “
Initialization by Turning OFF and ON the System
STEP 6
Set the data and time by using ATIM.
[End]
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
CF card cannot be removed while the SV8500 is in operation. Doing so stops the system
operation.
WARNING
Be sure to use anti-static measures when handling a CF card. See “
for more details.
WARNING
Summary of Contents for SV8500
Page 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Page 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Page 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Page 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Page 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Page 973: ......
Page 974: ...Printed in Japan 0901 020...
Page 975: ......