– 673 –
CHAPTER 5
Operation Procedure for System with PIR
5.6.3
PIR Power ON/OFF Procedure
[Turn ON/OFF Procedure: AC-Powered Model of PIR]
Turn ON:
STEP 1: Connect an AC power code to AC inlet on AC-DC Power Unit. AC-DC Power
Unit is powered on here (OPE lamp lights and fans start turning).
STEP 2: Turn on the PWR switch (to right) on the front right of AC-DC Power Unit. AC-DC Power Unit starts
supplying the power to PIR here.
STEP 3: Flip the -48V SW switch up on the PWR/DPWR card in each PIR.
Turn OFF:
STEP 1: Flip the -48V SW switch down on the PWR/DPWR card in each PIR.
STEP 2: Turn off the PWR switch (to left) on the front right of AC-DC Power Unit.
STEP 3: Disconnect the AC power code.
[Turn ON/OFF Procedure: DC-Powered Model of PIR]
Turn ON:
STEP 1: Supply the power to BASEU. When the power cable connection between BASEU and PIR is com-
pleted, BASEU starts supplying the power to PIR here.
STEP 2: Flip -48V SW switch up on the PWR/DPWR card in each PIR.
Turn OFF:
STEP 1: Flip the -48V SW switch down on the PWR/DPWR card in each PIR.
STEP 2: Stop supplying the power to BASEU.
ATTENTION
Contents
Static Sensitive
Handling
Precautions Required
Summary of Contents for SV8500
Page 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Page 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Page 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Page 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Page 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Page 973: ......
Page 974: ...Printed in Japan 0901 020...
Page 975: ......