CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-CP15 (FP)
NEAX2000 IVS
2
Installation Procedure Manual
Page 240
ND-70928 (E), Issue 3.0
Switch Settings
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
NOTE 1: Set the groove on the switch to the desired position.
NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/
unplugging the circuit card.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SENSE
(Rotary SW)
NOTE 1
0-3
For setting FP No.
0
For mounting this card in PIM 0
1
For mounting this card in PIM 2
2
For mounting this card in PIM 4
3
For mounting this card in PIM 6
4-F
Not used
MB (Toggle SW)
NOTE 2
UP
For make-busy
For normal operation
SW1
(Piano Key SW)
1 - 3
Not used
4
For normal operation
OFF
Not used
0
1
2
3
ON
DOWN
4
3
2
1
OFF
ON
OFF
ON