CHAPTER 2 INSTALLATION
Termination Of Cables On MDF
NEAX2000 IVS
2
Installation Procedure Manual
Page 132
ND-70928 (E), Issue 3.0
MDF Cross Connections
This table shows the cross connections on the MDF for LTC0 - LTC3.
Table 2-4 LTC0 - LTC3 MDF Cross Connection
PIN
RUNNING
CABLE
STATION
CABLE
SLOTS
TYPE OF INTERFACE
CO
LDT
2-W
E&M
4-W
E&M
DID
SLT
8COT 4COT 2LDT 4LDT 2ODT 2ODT AUC 4DIT 8LC 4LC AUC
26
WH-BL
GN
1
T0
T0
T0
T0
T0
TxT0
T0
T0
T0
T0
T0
1
BL-WH
RD
R0
R0
R0
R0
R0
TxR0
R0
R0
R0
R0
R0
27
WH-OR
BK
T1
T1
T1
T1
RcvT0 T1
T1
T1
T1
T1
2
OR-WH
YL
R1
R1
R1
R1
RcvR0 R1
R1
R1
R1
R1
28
WH-GN
GN
T2
T2
T2
T1
TxT1
T2
T2
T2
3
GN-WH
RD
R2
R2
R2
R1
TxR1
R2
R2
R2
29
WH-BR
BK
T3
T3
T3
RcvT1
T3
T3
T3
4
BR-WH
YL
R3
R3
R3
RcvR1
R3
R3
R3
30
WH-SL
GN
T4
T4
5
SL-WH
RD
R4
R4
31
RD-BL
BK
T5
T5
6
BL-RD
YL
R5
R5
32
RD-OR
GN
T6
T6
7
OR-RD
RD
R6
R6
33
RD-GN
BK
T7
T7
8
GN-RD
YL
R7
R7
NOTE 1:
PIN No. 46, 21 to 49, 24 on LTC3 cannot be used.
NOTE 2:
PIN No. 46, 21 to 49, 24 on LTC2 and LTC3 cannot be used.
NOTE 3:
For the Digital Trunk Interface card, use the different LTC connector from the analog line/trunk
card. The digital line should be separated from the analog line.