CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-SC00 (CCH)
NEAX2000 IVS
2
Installation Procedure Manual
Page 382
ND-70928 (E), Issue 3.0
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
NOTE 1: Set the groove on the switch to the desired position.
NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/
unplugging the circuit card.
NOTE 3: This setting is available when SW0-2 is set to ON (Analog Interface).
NOTE 4: The following two kinds of rate adaptation methods are available in 48 kbps data
transmission. The rate adaptation method must be set to match the rate adaptation of
the clock source office.
SW1(DIP SW)
1
ON
• Common channel signaling data
transmission speed (For Digital
Interface)
• Common channel signaling data
transmission speed (For Analog
Interface)
Set switches (SW1-1 - SW1-5) to
OFF.
OFF
2
ON
OFF
3
ON
OFF
4
ON
OFF
5
ON
OFF
6
ON
A-law
OFF
µ
-law
7
Always set to OFF
8
Always set to OFF
SWITCH
NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
1 2 3 4 5 6 7 8
ON
TRANSMISSION
SPEED
SW
1-1
SW
1-2
SW
1-3
SW
1-4
SW
1-5
48 kbps NOTE 4
ON
ON
OFF
OFF
ON
48 kbps NOTE 4
ON
ON
ON
OFF
ON
56 kbps
ON
ON
OFF
ON
ON
64 kbps
ON
ON
ON
ON
ON
OFF
OFF
1
1
48 kbps
Data
• SW1-3: OFF
1
1
48 kbps
• SW1-3: ON
Data