CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-SC03-B (CSH/ICH)
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 3.0
Page 391
Switch Settings
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
NOTE 1: Set the groove on the switch to the desired position.
NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/
unplugging the circuit card.
NOTE 3: When the U-interface CS (ZT) is used, one CSH card per system must be set to the
SW1-1 switch ON. And mount the CSH card which SW1-1 is set to ON into PIM 0.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SENSE
(Rotary SW)
NOTE 1
4-F
Set the switch to match the AP number (04-31) to
be set by CM05.
0-3
Not used
MB (Toggle SW)
NOTE 2
UP
For make-busy
For normal operation
SW1
(Piano SW)
1
NOTE 3
ON
60 ms synchronization clock ON
OFF
60 ms synchronization clock OFF
2
Not used
3
Not used
4
ON
AP No. 04-15
OFF
AP No. 20-31
F
4
AP No.
SW1-1: ON
04 05 06 07 08 09 10 11 12 13 14 15
SW1-1: OFF 20 21 22 23 24 25 26 27 28 29 30 31
SW No.
4
5
6
7
8
9
A
B
C
D
E
F
ON
DOWN
4
3
2
1
OFF
ON
OFF
OFF