CHAPTER 2 INSTALLATION
BACKUP CPU SYSTEM
NEAX2000 IVS
2
Installation Procedure Manual
Page 226
ND-70928 (E), Issue 3.0
•
When Using Key FD
(1)
Set the SW3 switch on the MP0 card to 2/3 (Off-line), and mount the MP0 card into MP00
slot.
(2)
Turn the system power ON.
(3)
Connect the MAT to the MP0 card, and clear all system data by CM00.
(4)
Assign the necessary office data to the MP0 card.
Date and time must be assigned by CM02.
(5)
Set the SW3 switch on the MP0 card to 0 (On-line).
(6)
Load the Key FD data to the MP0 card.
(7)
Turn the system power OFF, then unplug the MP0 card from MP00 slot once.
(8)
Set the SW3 switch on the MP1 card to 2/3 (Off-line), and mount the MP1 card into MP01
slot.
(9)
Turn the system power ON.
(10) Connect the MAT to the MP1 card, and clear all system data by CM00.
(11) Set the SW3 switch on the MP1 card to 0 (On-line).
(12) Load the Key FD data to the MP1 card.
(13) Flip the MB switch on the MP0 and MP1 cards to ON (UP position), and mount the MP0
card to MP00 slot again.
(14) Turn the system power ON.
(15) Flip the MB switch on the MP0 card to OFF (DOWN position), and confirm if the RUN lamp
on the MP0 card lights.
(16) Flip the MB switch on the MP1 card to OFF (DOWN position).
- The MP0 acts. The RUN lamp on the MP0 card flashes at 120 IPM.
- The MP1 card comes into a stand by mode. The STBY lamp lights and the RUN lamp
flashes in a slow pace, on the MP1 card.
- 3 to 6 minutes later, the office data copy from the MP0 to MP1 card starts. The RUN lamp
on the MP1 card flashes intermittently.
- When the office data copy finishes (maximum 20 minutes later), the RUN lamp on the
MP1 card flashes in a slow pace.