CHAPTER 2 INSTALLATION
Battery Connection
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 3.0
Page 109
External / BATTM Battery Connection
(1)
Connect the BATT CA EXT cable to the batteries as shown below.
(2)
Mount the battery units (24V DC, 24AH per unit) into the Battery Module (BATTM), if the
BATTM is required.
(3)
Plug the BATT CA EXT connector into the BATT1 connector on the PZ-PW121/PZ-PW126
card in PIM 0 or PIM 4.
NOTE:
Screws are attached to the BATTM.
Figure 2-40 Battery Mounting into BATTM
Recommended Batteries
Yuasa NP-24-12B
Matsushita LCL-12V-24
DIMENSION OF BATTERY
175 mm
(6.9 inch)
125 mm
(4.9 inch)
165 mm
(6.5 inch)
BATTERY UNIT
(24V DC, 24AH)
BATTERY UNIT
(24V DC, 24AH)
BATT CA EXT
TO BATT1 CONNECTOR
ON PZ-PW121/PZ-PW126
IN PIM 0/PIM 4