CHAPTER 2 INSTALLATION
Wall Mounting Installation
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 3.0
Page 83
• Hanging PIM to HANGER ASSEM
(1) Secure the HANGER ASSEM to the surface of a wall with three screws.
Select screws to match with the wall type as follows.
A concrete wall is recommended because it is the most firm to mount the PBX. The
plaster board is the least firm wall of the three.
(2) Hang the slits of the rear of a PIM to the hooks of the HANGER ASSEM.
(3) Secure the PIM to the HANGER ASSEM with two screws.
NOTE:
Screws are attached to the HANGER ASSEM.
WALL TYPE
RECOMMENDED SCREW
CONCRETE
ANCHOR BOLT TYPE
• Recommended 4 mm (0.16 inch) by 25 mm (0.98 inch)
WOOD
WOOD TYPE SCREWS
• Minimum 3.5 mm (0.14 inch) DIA
• Maximum 4.5 mm (0.17 inch) DIA
PLASTER BOARD
[THICKNESS Minimum 9.6 mm
(0.38 inch)]
MOLLY ANCHOR TYPE
• Minimum 3.5 mm (0.14 inch) DIA
• Maximum 4.5 mm (0.17 inch) DIA