CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PZ-VM00-M (VM)
NEAX2000 IVS
2
Installation Procedure Manual
Page 388
ND-70928 (E), Issue 1.0
Switch Settings
The figure in the SWITCH NAME column and the position in
the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
NOTE 1: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
ging the circuit card.
NOTE 2: When SW1 settings have changed, RST switch must be pushed.
NOTE 3: Use BIOS Redirect only when assisted by NEC.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
MB (Toggle SW)
NOTE 1
UP
For make-busy
For normal operation
RST (Toggle SW)
NOTE 2
Push when starting up this card, after MB switch is
set to DOWN position.
SW1
(Piano Key SW)
NOTE 2
1
ON
BIOS Redirect Utility (Key board)
NOTE 3
Normal Operation
2
ON
BIOS Redirect Utility (Floppy Drive)
NOTE 3
Normal Operation
3
ON
COM2: Use internal modem for
remote maintenance
OFF
COM2: RS-232C (For local direct
connection to maintenance console)
4
Not used
ON
DOWN
4
3
2
1
OFF
ON
OFF
OFF
OFF