CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-4RSTB (MFR)
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 1.0
Page 301
Switch Settings
NOTE 1: Set the groove on the switch to the desired position.
NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
ging the circuit card.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
SENSE
(Rotary SW)
NOTE 1
4-F
Set the switch to match the AP Number (04-31) to
be set by CM05
0-3
Not used
MB (Toggle SW)
NOTE 2
UP
For make-busy
For normal operation
SW
(Piano Key SW)
1
ON
For make-busy No. 0 circuit
For normal operation
2
ON
For make-busy No. 1 circuit
For normal operation
3
ON
For make-busy No. 2 circuit
For normal operation
4
ON
For make-busy No. 3 circuit
For normal operation
5
Not used
6
7
8
ON
AP No. 04-15
OFF
AP No. 20-31
F
4
AP No.
SW-8: ON
04 05 06 07 08 09 10 11 12 13 14 15
SW-8: OFF
20 21 22 23 24 25 26 27 28 29 30 31
SW No.
4
5
6
7
8
9
A
B
C
D
E
F
ON
DOWN
OFF
ON
5
6
7
8
1
2
3
4
OFF
OFF
OFF
OFF
OFF
OFF
OFF