CHAPTER 2 INSTALLATION
Battery Connection
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 1.0
Page 95
CAUTION
3. Battery Replacement Table and Battery Warnings
The label which shows battery replacement table and battery warnings is attached to the
reverse side of Front Cover for PIM and BATTM.
During the battery installation process, the warning statements must be observed. When re-
placing batteries, the battery replacement table should be observed in order to increase bat-
tery life and insure a safe operation.
0 ~ 50°C
2 YEARS
(AVERAGE 25°C)
LABEL
PIM/BATTM
FRONT COVER
BATTERY REPLACEMENT TABLE
INSTALLATION DATE:
AMBIENT
TEMPERATURE
5 ~ 35°C
(AVERAGE 25°C)
REPLACEMENT
INTERVAL
3 YEARS
1 YEAR
CAUTION
TO PREVENT INJURY AND SKIN BURN,
PAY ATTENTION TO THE FOLLOWING.
o DO NOT STRIKE A MATCH OR CAUSE A SPARK IN
VICINITY OF BATTERY.
o PLACE THE EQUIPMENT WELL VENTILATED
AREA.
o DO NOT SHORT.
o REPLACE BATTERY ONLY AFTER BATTERY
GASES HAVE BEEN DISPERSED.
o ELECTROLYTE LEAKAGE OR OTHER HAZARDS
MAY RESULT IF THE BATTERY IS NOT REPLACED
IN ACCORDANCE WITH THE SPECIFIED INTER-
VALS.
(AVERAGE 40°C)
0 ~ 50°C