CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-AP01 (AP01)
NEAX2000 IVS
2
Installation Procedure Manual
ND-70928 (E), Issue 1.0
Page 237
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
NOTE 1: Set the groove on the switch to the desired position.
NOTE 2: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
ging the circuit card.
SW0 (DIP SW)
1
ON
Receives RT clock
Uses internal clock
2
ON
Receives ST2 clock
Uses internal clock
3
ON
Sends ST1 clock
Not send ST1 clock
4
Not used
J19
For normal operation
(Memory backup ON)
LEFT
Not used
(Memory backup OFF)
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
1 2 3 4
ON
OFF
OFF
OFF
OFF
Front
(Jumper pin)
RIGHT