CHAPTER 3 LAMP INDICATIONS AND SWITCH SETTINGS
PN-DAIB (DAI)
NEAX2000 IVS
2
Installation Procedure Manual
Page 260
ND-70928 (E), Issue 1.0
The figure in the SWITCH NAME column and the position in
in the SETTING POSITION
column indicate the standard setting of the switch. When the switch is not set as shown by the
figure and
, the setting of the switch varies with the system concerned.
NOTE 1: When the power is on, flip the MB switch to ON (UP position) before plugging/unplug-
ging the circuit card.
NOTE 2: Time slot number 0, 20, 21, and 22 (TS0/20/21/22) can not be used for control signal.
NOTE 3: This setting must be identical with the opposite DAIA card.
SW3 (DIP SW)
1
Set the equalizer according to the
cable length between the system
and the CSU.
OFF
2
OFF
3
OFF
4
Always set to OFF
JPS (Jumper pin)
UP
Neutral grounding on the transmit-
ting line is provided.
Neutral grounding on the transmit-
ting line is not provided.
JPR (Jumper pin)
UP
Neutral grounding on the receiving
line is provided.
Neutral grounding on the receiving
line is not provided.
SWITCH NAME
SWITCH
NUMBER
SETTING
POSITION
FUNCTION
CHECK
1 2 3 4
ON
ON
SW
-1
SW
-2
SW
-3
CABLE
LENGTH
ON
ON
ON
0 - 40m
(0-131.2ft.)
ON
ON
OFF
40 - 80m
(131.2-262.5ft.)
ON
OFF
ON
80 - 120m
(262.5-394ft.)
ON
OFF OFF
120 - 160m
(394-525ft.)
OFF
ON
ON
160 - 200m
(525-656ft.)
OFF OFF OFF
Signal is not sent
ON
ON
OFF
DOWN
DOWN