CHAPTER 14 SERIAL INTERFACE CHANNEL 1
264
User’s Manual U11302EJ4V0UM
Figure 14-4. Format of Automatic Data Transmit/Receive Control Register
Notes 1.
Bits 3 and 4 (TRF and ERR) are read-only bits.
2.
The termination of automatic transmission/reception should be judged by using TRF, not
CSIIF1 (interrupt request flag).
Caution When external clock input is selected with bit 1 (CSIM11) of serial operating mode
register 1 (CSIM1) set to 0, set STRB and BUSY1 of ADTC to 0, 0.
Remark
×
: don’t care
<6>
<5>
<4>
<3>
<2>
<1>
<0>
<7>
Symbol
ADTC
RE
ARLD ERCE ERR
TRF
STRB
BUSY1 BUSY0
FF69H 00H R/W
Note 1
Address After reset R/W
BUSY1
0
1
1
Busy input control
Not using busy input
Busy input enabled (active high)
Busy input enabled (active low)
BUSY0
×
0
1
STRB
0
1
Strobe output control
Strobe output disabled
Strobe output enabled
TRF
1
Status of automatic transmit/receive function
Note 2
Detection of termination of automatic transmission/
reception (This bit is set to 0 upon suspension of
automatic transmission/reception or when ARLD = 0.)
During automatic transmission/reception
(This bit is set to 1 when data is written to SIO1.)
R/W
R/W
R
R
ERR
0
1
Error detection of automatic transmit/receive
function
No error
(This bit is set to 0 when data is written to SIO1.)
Error occurred
R/W
ARLD
0
1
Operating mode selection of automatic transmit/
receive function
Single operating mode
Repetitive operating mode
R/W
RE
0
1
Receive control of automatic transmit/receive
function
Receive disabled
Receive enabled
R/W
ERCE
0
Error check control of automatic transmit/
receive function
Error check disabled
Error check enabled (only when BUSY1 = 1)
0
1