CHAPTER 6 16-BIT TIMER/EVENT COUNTER
136
User’s Manual U11302EJ4V0UM
Figure 6-11. Interval Timer Operation Timing
Remark
Interval time = (N + 1) x t: N = 0001H to FFFFH
Table 6-5. 16-Bit Timer/Event Counter Interval Time
TCL06 TCL05 TCL04
Minimum Interval Time
Maximum Interval Time
Resolution
0
0
0
2 x TI0 input cycle
2
16
x TI0 input cycle
TI0 input edge cycle
0
0
1
2 x 1/f
X
(400 ns)
2
16
x 1/f
X
(13.1 ms)
1/f
X
(200 ns)
0
1
0
2
2
x 1/f
X
(800 ns)
2
17
x 1/f
X
(26.2 ms)
2 x 1/f
X
(400 ns)
0
1
1
2
3
x 1/f
X
(1.6
µ
s)
2
18
x 1/f
X
(52.4 ms)
2
2
x 1/f
X
(800 ns)
1
0
0
2
4
x 1/f
X
(3.2
µ
s)
2
19
x 1/f
X
(104.9 ms)
2
3
x 1/f
X
(1.6
µ
s)
Other than above
Setting prohibited
Remarks 1.
f
X
: Main system clock oscillation frequency
2.
Figures in parentheses apply to operation with f
X
= 5.0 MHz.
t
0000
TM0 count value
Count clock
CR00
INTTM0
TO0
0001
N
0000
0001
N
0000
0001
N
Count start
Clear
Clear
Interrupt request acknowledgment
N
N
N
N
Interval time
Interval time
Interval time
Interrupt request acknowledgment